Language:
Colors:

Lambert Lx 24 Fi Manual English [best]

The Lx 24 Fi is a combi boiler, not a storage heater. It heats water on demand. If delay exceeds 30 seconds, check pre-heat mode (if available) or consider a secondary circulation system.

Baxi Lambert LX 24 Fi | PDF. 100%(1)100% au considerat acest document util (1 vot) 4K vizualizări10 pagini. Baxi Lambert LX 24 Fi. How to reset a Baxi boiler | Baxi Guides

Includes a filter and a system filling loop connection.

Detailed technical documentation and user guides can be accessed via Scribd or through official Baymak resources. Gas boiler Baymak Lambert LX 24 FI P EXP 24 kWt Lambert Lx 24 Fi Manual English

: Overheating protection has been triggered because the main heat exchanger exceeded safe thermal limits.

Owning a Lambert Lx 24 Fi boiler means enjoying reliable, efficient heating and hot water, but only if you operate and maintain it according to the manufacturer’s instructions. This guide has extracted the most critical information from the version, including control operations, error code solutions, repressurising steps, and safety warnings.

The Lx 24 Fi model is a "room sealed" (Fi) fan-assisted boiler, meaning it draws combustion air from outside and exhausts gases through a coaxial chimney system, making it safe for modern indoor installation. Key Technical Specifications The Lx 24 Fi is a combi boiler, not a storage heater

Requires a 220-230 V grounded power supply. If voltage fluctuates outside the 195 V – 255 V range, a voltage regulator is recommended.

Complete User and Installer Guide for the Lambert Lx 24 Fi Boiler

The boiler will display an error code and shut down to protect the heat exchanger. Open the black filling loop valve underneath the boiler until the needle reaches 1.2 bar, then close the valve completely. Baxi Lambert LX 24 Fi | PDF

| Specification | Details | |:---|:---| | Product Type | Conventional (On-Demand) Combination Boiler | | Model Name | Lambert Lx 24 Fi | | Power Output | 24 kW | | Max. Heating Capacity | Approximately 160 m² (subject to building insulation) | | Dimensions (HxWxD) | 725 mm x 400 mm x 300 mm | | Weight | 38 kg | | Expansion Vessel Capacity | 6 liters | | Domestic Hot Water Flow Rate | 10.7 liters per minute | | Max. Radiator (CH) Temp | 20°C - 80°C | | Max. Domestic Hot Water (DHW) Temp | 30°C - 65°C | | Electrical Power Consumption | 135 W | | Electrical Protection Rating | IPX4D (Splash-proof) | | NOx Class | 3 (Environmental standard) | | Color | White |

Incorrect venting or a faulty exhaust fan/air pressure switch.

Check if the main gas supply valve is open. Turn the selector switch to for 2 seconds. If it persists, the ignition electrode or gas valve may be faulty. E02 Safety Thermostat Overheat Fault

If the pressure gauge falls below 0.8 bar, the boiler may lock out (error E03). To repressurise: